EasyManua.ls Logo

EDM Solution Ultima 844 - Defaulting the Control Panel

Default Icon
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming 119
Defaulting The Control Panel
If the Solution Ultima 844/862/880 control panel does not have "LOCATION 900"
programmed as 15, follow the procedure outlined below to successfully default the control panel back
to the factory default settings.
How To Default The Control Panel Via Installer Code
1. Enter Installer Programming Mode.
(e.g..
1234 followed by the # button). Two beeps will be heard. The STAY and
AWAY indicators will begin to flash to indicate that you have accessed programming mode.
2. Enter Installer’s Programming Command
961followed by the #button.
Two beeps will be heard after the control panel has successfully been defaulted.
3. Enter Installer’s Programming Command 960 followed by the # button.
Two beeps will be heard. The
STAY and AWAY indicators will cease to flash and the system
will return to the disarmed state.
The control panel has now been successfully defaulted back to the factory default settings.
How To Default The Control Panel Via Default Button
1. Disconnect the AC mains supply and the backup battery from the control panel.
2. Hold down and continue to hold down the DEFAULT button.
The default button is located at the top of the PCB next to the PROGRAMMING KEY
connecting socket.
3. Reconnect the AC mains supply to the control panel.
4. After reconnecting the AC mains supply, wait for 3-5 seconds before releasing the DEFAULT
button.
5. Disarm the system using the default Master Code (e.g.. Enter
2580 followed by the #
button).
The control panel has now been successfully defaulted back to the factory default settings.
If you hear the dialler seize relay (RL2) click four times while attempting to default the control
panel, this would indicate that the feature of defaulting the control panel has been disabled in
“LOCATION 900” on page 118. The control panel will need to be returned to Electronics Design
and Manufacturing Pty Limited for exchange where a service fee will be charged to unlock the
control panel's memory if the Installer Code is not known.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC