190 Solution Ultima 844/862/880 Installation Manual
Codepad Duress Report
LOCATION 348 6
Location Description
348
Codepad Duress Report
Table 101: Codepad Duress Report Location
A "Duress" report (Contact ID Event Code 121) will be sent to the base station receiver when the
9
button is added to the end of any valid user code being used to disarm the system. This alarm will
always be silent. A duress alarm can be triggered during exit time (i.e.. If the system has been armed
and then disarmed by adding the
9button to the end of the user code before exit time has expired, a
"Duress" report will be sent). Adding
9 to the end of a user code when arming the system will not
cause a duress alarm.
Refer to Option 2 in “LOCATION 442” on page 233 if you wish to add the
3 button to the end of
the user code being used to disarm the system.
Restore reports are not sent for this event. If a "Duress" report is not required, program
"LOCATION 348" with a zero.
Codepad Panic Report
LOCATION 349 - 350 7
Location Description
349
Codepad Panic Reporting Code (Tens Digit)
350
Codepad Panic Reporting Code (Units Digit)
Table 102: Codepad Panic Report Locations
A "Panic Alarm" report (Contact ID Event Code 120) will be sent to the base station receiver when
either the two outside buttons
1 and 3 or and are pressed simultaneously. This is an
audible alarm. Refer to Option 1 in "LOCATION 437" on page 228 if you require codepad panic to
be silent.
Restore reports are not sent for this event. If a "Panic" report is not required, program
"LOCATION 349 - 350" with a zero.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited