Dialler Options 153
Dialler Options 1
LOCATION 177 9
Option Description
1
Dialler Reporting Functions Allowed
2
Remote Arming Via The Telephone Allowed
4
Answering Machine Bypass Only When Armed
8
Use Bell 103 For FSK Format (Disabled = CCITT V21)
1
2
4
8
Table 71: Dialler Options 1
Dialler Reporting Functions Allowed
If this option has been selected, the dialler will function for all operations. Upload/Download via
Alarm Link Software (CC816) and telephone remote arming will remain operational regardless of this
setting.
Disabled = Disable All Dialler Reporting Functions
If this option is not selected, the communication dialler will not operate. Upload/Download via Alarm
Link Software (CC816) and telephone remote arming will remain operational regardless of this
setting.
Remote Arming Via The Telephone Allowed
If this option has been selected, you can remotely arm the system via a standard telephone using the
Phone Controller (CC911) or by pressing the
* button on your touch-tone telephone. Refer to
Remote Arming Via The Telephone on page 100 for more information. Forced arming is
automatically assumed when this feature is being used. Refer to Zone Options 2 on page 179 for more
information on forced arming.
If the dialler has been disabled, it will have no effect on remote arming via the telephone. Refer to
Ring Count on page 148 for programming the number of rings before the control panel will answer an
incoming call.
Answering Machine Bypass Only When Armed
This option needs to be selected if the answering machine bypass feature is required to operate only
when the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2. When the
system is disarmed, the control panel will not answer any incoming calls. This option is beneficial in
high telephone traffic installations where the control panel could answer an incoming call. Refer to
Ring Count on page 148 to program answering machine bypass.
Use Bell 103 For FSK Format (Disabled = CCITT V21 Format)
If this option is enabled, the control panel will use the transmission frequency BELL 103 at 300 baud.
If this option is disabled, the control panel will use the transmission frequency CCITT V21 at 300
baud.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC