76 Solution Ultima 844/862/880 Installation Manual
Master Code Functions
Master Code Functions are designed to allow those users that have the appropriate priority level to
perform certain functions of a supervisory level. These functions can only be carried out when the
system is in the disarmed state.
0
The default Master Code is 2580 and is known as User Code 1. It is possible for the
system to have multiple Master Codes. Refer to "User Code Priority" on page 161 for more
information.
To enter the required Master Code function, enter the
followed by the required
digit and the button. All available Master Code functions are listed in “Table 36:
Master Code Functions” outlined below.
+ +
Table 36: Master Code Functions
Arm or Disarm Both Areas At The Same Time
This Master Code function only operates on Solution Ultima 880 systems that have been
partitioned. The Master Code function allows those Master Code user codes that are allocated to both
Area 1 and Area 2 to arm or disarm both areas at the same time.
This allows the user to ensure that both areas will be armed or disarmed by pressing one extra button
rather that entering a code twice to ensure both areas are armed or disarmed. This function can be
used to arm both areas at the same time from either the CP5 Area Addressable Codepad (CP500A) or
the Master Partitioned Codepad (CP500P). Refer to Option 2 in “LOCATION 445” on page 242 to
enable this feature.
How To Arm/Disarm Both Areas At The Same Time
1. Enter your followed by 0and the button.
Two beeps will be heard and both areas will be armed or disarmed from AWAY Mode.
+
0
+
Function Description Page
0
Arm Or Disarm Both Areas At The Same Time 76
1
Changing and Deleting User Codes/Radio Codes 77/79
2
Changing Domestic Phone Numbers 81
3
Changing Telco Arm/Disarm Sequence 83
4
Setting STAY Mode 2 Zones 86
5
Turning Outputs On/Off 87
6
Setting The Date and Time 89
7
Walk Test Mode 90
8
Event Memory Recall Mode 91