EasyManua.ls Logo

EDM Solution Ultima 844 - Open;Close Reporting Options; Open;Close Reports

Default Icon
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Reporting Information 189
Open/Close Reports
LOCATION 345 - 346
Location Description
345
Opening Report
346
Closing Report
Table 99: Open/Close Reporting Locations
An "Opening" report (Contact ID Event Code 401) will be sent to the base station receiver when the
system has been disarmed from AWAY Mode. A "Closing" report (Contact ID Event Code 401) is
sent at the end of exit time when the system has been armed in AWAY Mode.
If an expanded format has been selected, this code will be used as the expansion code and the user
number that armed or disarmed the system will follow in the same transmission.
Refer to Option 2 in "LOCATION 178" on page 154 for programming "Open/Close" reports in STAY
Mode. To program "Open/Close" reports only after a previous alarm, refer to Option 1 in
"LOCATION 178" on page 154.
If you do not require "Open/Close" reports, program "LOCATION 345 - 346" with zero.
Solution Ultima 880 control panels that have been partitioned will send Open/Close reports with
a Contact ID Event Code 402
Open/Close Reporting Options
LOCATION 347
Option Description
0
No Report Required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and Receiver 2
8
Receiver 2 Only When Receiver 1 Fails
Table 100: Open/Close Reporting Options Location
This location is factory default to report only to Receiver 1. You can select whether the open/close
reports will report on Receiver 1, Receiver 2, both Receiver 1 and Receiver 2, Receiver 2 only when
Receiver 1 fails or no reporting at all.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC