System Functions 93
Hold Down Functions
Hold down functions have been incorporated to allow easy activation of specific operations. When a
button is held down for two seconds, two beeps will be heard and a particular function will operate.
The hold down functions available are listed below.
Arm The System In AWAY Mode
#
Holding the #button down until two beeps are heard will arm the system in AWAY Mode. Option 2
in "LOCATION 441" on page 232 will need to be enabled for this hold down function to operate.
This hold down function will not operate on Solution Ultima 880 control panels when
partitioned using the CP5 Master Partitioned codepad (CP500P). Holding the # button down
until two beeps are heard on a CP5 Area Addressable codepad (CP500A) will arm the
corresponding area in AWAY Mode.
Arm The System In STAY Mode 1
Holding the *button down until two beeps are heard will arm the system in STAY Mode 1. Option
2 in "LOCATION 441" on page 232 will need to be enabled for this hold down function to operate.
If there has not been an alarm during the armed cycle, holding the
*button down a second time will
disarm the system from STAY Mode 1. If you require single button disarming from STAY Mode 1
using this hold down function, Option 4 in "LOCATION 441" on page 232 will need to be enabled.
If an alarm has occurred or entry warning has triggered, a valid user code will need to be used to
disarm the system.
Refer to Zone Options 2 on page 179 for information on programming each zone to be automatically
isolated in STAY Mode 1.
*
This hold down function will not operate on Solution Ultima 880 control panels when
partitioned using the CP5 Master Partitioned codepad (CP500P). Holding the
* button down
until two beeps are heard on a CP5 Area Addressable codepad (CP500A) will arm the
corresponding area in STAY Mode 1.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC