74 Solution Ultima 844/862/880 Installation Manual
Walk Test Mode
7
Walk test mode allows you to test detection devices to ensure that they are functioning correctly.
Before activating walk test mode, isolate any zones that are not required for testing. Refer to Isolating
Zones on page 48 for further information. Refer to LOCATION 327 - 328 on page 184 to program
walk test mode reports.
How To Enter Walk Test Mode
1. Enter your followed by 7and the button.
Three beeps will be heard and the
STAY and AWAY indicators will begin to flash. The
codepad will beep once every second while the system is in walk test mode.
2. Unseal and seal the zones to be tested.
The codepad will sound one long beep and the horn speaker will sound one short beep every
time a zone is sealed or unsealed.
3. Press the
button to exit this function.
Two beeps will be heard and the
STAY and AWAY indicators will extinguish. The system has
now returned to the disarmed state.
+
7
+
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited