Dialler Information 141
Transmission Format For Receiver 1
LOCATION 033 1
Enter the desired transmission format here. This location selects the data format that will be sent to
the base station receiver. This location also allows you to configure the control panel for domestic or
basic pager formats.
Option Transmission Format Option Transmission Format
1
Contact ID
4
Domestic
2
4 + 2 Express
5
Basic Pager
3
FSK (300 Baud) BELL
Table 62: Transmission Formats For Receiver 1
Subscriber ID Number For Receiver 1
LOCATION 034 – 039 000000
This number is sent to identify the calling control panel. Enter the desired Subscriber ID Number in
the six locations provided.
For Basic Pager Format, “LOCATION 034 – 036” will be ignored and the first digit of the Subscriber
ID Number required must start in “LOCATION 037”.
When using Domestic Dialling Format, the number of identification beeps will be the number that is
programmed in “LOCATION 039”. This gives the ability to identify between 15 different control
panels calling the same telephone number.
Example
If you wish to program the Subscriber ID Number as 4729, you would program the six locations as
follows:
004729