24 Solution Ultima 844/862/880 Installation Manual
Solution Ultima 844 Zone Defaults
The default zone settings of the control panel are listed in the table below. Zones 1 – 4 may be
programmed to any of the available zone types. Zones 5 – 8 are limited to that they may only be
programmed to any 24 hour or keyswitch type. Refer to “Table 4: Available Zone Types” on page 25
for the different zone types that may be selected.
Zone No Zone Type Zone No Zone Type
1
Delay-1
5
24 Hour Burglary
2
Handover
6
24 Hour Burglary
3
Handover
7
24 Hour Fire
4
Instant
8
24 Hour Tamper
Table 1: Zone Defaults For Solution Ultima 844
Solution Ultima 862 Zone Defaults
The default zone settings of the control panel are listed in the table below. Zones 1 – 6 may be
programmed to any of the available zone types. Zones 7 and 8 are limited to that they may only be
programmed to any 24 hour or keyswitch type. Refer to “Table 4: Available Zone Types” on page 25
for the different zone types that may be selected.
Zone No Zone Type Zone No Zone Type
1
Delay-1
5
Instant
2
Handover
6
Instant
3
Handover
7
24 Hour Fire
4
Handover
8
24 Hour Tamper
Table 2: Zone Defaults For Solution Ultima 862
Solution Ultima 880 Zone Defaults
The default zone settings of the control panel are listed in the table below. Zones 1 – 8 may be
programmed to any of the available zone types. Refer to “Table 4: Available Zone Types” on page 25
for the different zone types that may be selected.
Zone No Zone Type Zone No Zone Type
1
Delay-1
5
Instant
2
Handover
6
Instant
3
Handover
7
Instant
4
Handover
8
24 Hour Tamper
Table 3: Zone Defaults For Solution Ultima 880
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited