Consumer Options 1
LOCATION 440 0
Option Description
1
Test Reports Only When Armed
2
Test Report After Siren Reset
4
Auto Arm In STAY Mode 1
8
STAY Indicator To Display Day Alarm Status
1
2
4
Table 143: Consumer Options 1
Test Reports Only When Armed
If this option has been selected, test reports (Contact ID Event Code 602) will only be sent when the
system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2. It is no longer necessary
to send a test report as well as an opening and closing report every day.
During the working week, most commercial premises would be open and therefore a test report is not
necessary, as open and close reports would be sent at the time programmed. If you wish to manually
send a test report, hold down the
9button until two beeps are heard.
Refer to Test Reporting Time on page 197 to set the test report time required. To set the first test
report, refer to the Installer Code Function – Set The Number Of Days Until The First Test Report on
page 65.
Test Report After Siren Reset
Selecting this option will force the control panel to send a test report after the siren has reset. This can
be used to indicate to the monitoring station that the control panel itself has not been tampered with
during the alarm period.
Auto Arm In STAY Mode 1
If automatic arming in STAY Mode 1 is preferred to automatic arming in AWAY Mode, this option
will need to be selected.
Refer to “LOCATION 426 - 429” on page 220 to program the time that the control panel will
automatically arm itself and “LOCATION 425” on page 220 to set the auto arming pre-alert time.
When using this option with a partitioned Solution Ultima 880 control panel, both areas will
automatically arm in STAY Mode 1.
STAY Indicator To Display Day Alarm Status
8
If this option has been selected, the STAY indicator will be used to display when day alarm has been
enabled. The
STAY indicator will flash once every 3 seconds while day alarm is active.
Refer to “LOCATION 265” on page 164 for programming zones to operate for day alarm operation.
Day alarm can be turned on and off by holding down the
4 button for 2 seconds. Three beeps
indicate day alarm is turned on and two beeps indicate day alarm is turned off. Refer to Day Alarm
Operation on page 165 for more information.