122
Solution Ultima 844/862/880 Installation Manual
Alarm Link Software
The Solution Ultima 844/862/880 control panel can be remotely programmed or controlled
via an IBM or compatible personal computer via the Alarm Link Software (CC816). This facility will
allow you to make alterations to your customers control panel without the need to leave your office,
thus improving customer service and saving you time and money. For country locations where a
control panel may be situated hundreds of kilometres from your office, the Upload/Download feature
is invaluable.
When selecting the control panel type during the set up of a new customer database in the Alarm Link
Software, refer to the table below to select the software version number that corresponds to the control
panel type required.
Control Panels Software Version Select Panel Type
Solution Ultima 844 - 1.00
S844_V10
Solution Ultima 862 - 1.00
S862_V10
Solution Ultima 880 - 1.00
S880_V10
Table 51: Alarm Link Panel Forms
After selecting the correct panel type when adding a new customer in the Alarm Link Software, the
Subscriber ID Number and the Installer Code must match that of the control panel for synchronisation
when making connection to the control panel. If these two locations do not match that of the control
panel, the computer and the control panel will not synchronise.
Remote Connect
The remote connect feature allows you to establish a connection through the telephone network from
your IBM or compatible computer to the
Solution Ultima 844/862/880 control panel
anywhere in the country where a telephone line is present. The advantages of this are very obvious
and having this facility will allow you to offer faster service to your clients.
Remote Connect With Customer Control
If you wish to configure the control panel so that a remote connection can only be established when
the client initiates it through the remote codepad, you will need to program the following information.
"LOCATION 159 - 174" on page 147 will need to have the Call Back Telephone Number
programmed and Option 1 in "LOCATION 180" on page 124/156 will need to be disabled. The
control panel has now been set so that the client has control of when a remote connection can be
established.
To activate the control panel to dial the remote computer to establish a link, hold the
6button down
until two beeps are heard on the remote codepad.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited