40 Solution Ultima 844/862/880 Installation Manual
System Operations
This section explains the general operations of the system. The operations will explain how to arm
and disarm the system in the various modes, how to isolate zones, initiate codepad alarms and
determine any fault that may occur.
Arming The System In AWAY Mode
Arming the system in AWAY Mode is normally performed when you leave the premises and require
that all zones be activated in a ready state to detect any intrusion.
There are two different methods for arming the system in AWAY Mode. Method one is standard and
will always operate. Method two is optional and requires Option 2 in "LOCATION 441" to be
enabled on page 232.
If you require to isolate a zone(s) prior to arming the system in AWAY Mode, refer to Isolating Zones
on page 48.
Single button arming in AWAY Mode will report as user code number 16.
Method One
How To Arm The System In AWAY Mode
1. Enter your followed by the button.
Two beeps will be heard and the
AWAY indicator will illuminate. Exit time will now
commence.
+
Method Two
How To Arm The System In AWAY Mode
1. Hold down the button until two beeps are heard.
The
AWAY indicator will illuminate and exit time will now commence. Refer to Option 2 in
"LOCATION 441" on page 232 to enable single button arming in AWAY Mode.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will be
constantly illuminated on the remote codepad. The zone will again become an active part of the
system as soon as it has resealed (i.e.. If a window is left open after exit time has expired, the window
will not be an active part of the system until it has closed. Opening the window after exit time has
expired will cause an alarm condition).
Forced Arming
The feature of arming the system when a zone is not sealed is known as forced arming. Refer to Zone
Options 2 on page 179 to enable forced arming for each zone.
If the
AWAY indicator does not illuminate and a long beep is heard when attempting to arm the system
in AWAY Mode, forced arming is not permitted. If this is the case, you must ensure that all zones are
sealed or manually isolated before you can arm the system.