System Reporting Information 191
Codepad Fire Report
LOCATION 351 - 352 7
Location Description
351
Codepad Fire Reporting Code (Tens Digit)
352
Codepad Fire Reporting Code (Units Digit)
Table 103: Codepad Fire Report Locations
A "Fire Alarm" report (Contact ID Event Code 110) will be sent to the base station receiver when the
4 and 6 buttons are pressed simultaneously. This is an audible alarm. Refer to Option 2 in
"LOCATION 437" on page 228 if you require codepad fire to be silent. A distinct fire sound is
emitted through the horn speaker to indicate this type of alarm condition. The fire sound is different
to the burglary sound.
Restore reports are not sent for this event. If a "Fire" report is not required, program
"LOCATION 351 - 352" with a zero.
Codepad Medical Report
LOCATION 353 - 354 7
Location Description
353
Codepad Medical Reporting Code (Tens Digit)
354
Codepad Medical Reporting Code (Units Digit)
Table 104: Codepad Medical Report Locations
A "Medical" report (Contact ID Event Code 100) will be sent to the base station receiver when the
7
and
9 buttons are pressed simultaneously. This is an audible alarm. Refer to Option 4 in
"LOCATION 437" on page 228 if you require codepad medical to be silent.
Restore reports are not sent for this event. If a "Medical" report is not required, program
"LOCATION 353 - 354" with a zero.