System Event Timers 221
Auto Disarming Time
LOCATION 430 - 433 0000
Location Description
430
Actual Hour Of The Day (Tens Digit)
431
Actual Hour Of The Day (Units Digit)
432
Actual Minute Of The Day (Tens Digit)
433
Actual Minute Of The Day (Units Digit)
Table 132: Auto Disarming Time Locations
These locations are used to program the actual time of the day that the system will automatically
disarm itself from AWAY Mode, STAY Mode 1 or STAY Mode 2. This time must be set in 24 hour
format (i.e.. 10:30 PM would be programmed as 2230).
User code 16 will report when the feature of automatic disarming is used.
On
Solution Ultima 880 control panels that have been partitioned into two separate areas, both
areas will automatically disarm at the same time every day.
V1.00 – V1.07
The system failed to automatically disarm if the system was not programmed to automatically
arm. To solve the problem, we suggest that you program the automatic arming time as 25:00
hours if you only require the control panel to disarm.
Kiss-Off Wait Time
LOCATION 434
Location Description
434
Increments Of 500 ms (500 ms – 8 Sec’s)
Table 133: Kiss-Off Wait Time Location
This location sets the time that the control panel will wait for acknowledgment before resending the
report. This applies only to Contact ID Format and 4 + 2 Express Formats.
Speaker Beep Volume
LOCATION 435
Location Description
435
0 = No Beeps / 15 = Loudest Beeps
Table 134: Speaker Volume Location
This location allows you to adjust the volume of speaker beeps for remote radio operation.