Alarm Link Operations 123
Remote Connect Without Call Back Verification
Remote connect without call back verification can be handy where you have a need to perform
Upload/Download functions from multiple locations.
There are two methods that you may program so that the call back verification is disabled. It should
be noted that by using this feature you are reducing the security of the control panel.
Method One
Method one allows you to call the control panel from any remote location without the need of having
the control panel call back to the computer to establish a link. In using method one, the customer has
no access to initiate a modem call by holding down the
6button. The following locations need to be
programmed for this method to operate.
"LOCATION 159 - 174" on page 147 should be programmed as zeros. Option 1 in "LOCATION 180"
on page 124/156 will need to be enabled and Option 2 needs to be disabled. The control panel will
now allow a connection of the first call without calling the remote computer back to make contact.
Method Two
Method two allows you to program a call back telephone number so that the customer can still initiate
a modem call when required, but when calling the control panel via the computer from any remote
location, the control panel does not call back the remote computer to establish a link.
"LOCATION 159 - 174" on page 147 should have the call back telephone number programmed if
required. Option 1 in "LOCATION 180" on page 124/156 will need to be enabled and Option 2 needs
to be disabled.
The control panel will now allow a connection of the first call without calling the remote computer
back to make contact but still allow the customer to initiate a modem call by holding down the
6
button when required.
Remote Connect With Call Back Verification
Remote connect with call back verification offers the highest degree of data security by incorporating
a two level security check.
The first is the Installer Code combined with the Subscriber ID Number needs to match that of the
control panel. Secondly, the control panel will call back the programmed call back telephone number
to establish the valid connection. The "Call Back Telephone Number" is the telephone line that the
modem and computer has been connected to.
"LOCATION 159 - 174" on page 147 must be programmed with the Call Back Telephone Number
and both Option 1 and Option 2 in "LOCATION 180" on page 124/156 will need to be enabled.
Direct Connect
The direct connect feature has been incorporated giving the installer a simple method for
programming the
Solution Ultima 844/862/880 control panel at the office or on site visits
using a portable computer. There is no need for telephone lines or modems, which makes
programming of the control panel completed easily in minutes.
All that is required is the Direct Link Cable (CC808) connected to the correct serial port on your IBM
or compatible computer and the other end to the auxiliary module socket on the control panel.
When using the direct connect method of connecting to the control panel, Option 1 in “LOCATION
180” on page 124/156 does not require to be enabled. The direct connect method of programming or
operating the control panel will operate regardless of this option being set.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC