EasyManua.ls Logo

EDM Solution Ultima 844 - Access Denied to be Silent; Codepad Fire to be Silent; Codepad Medical to be Silent; Codepad Panic to be Silent

Default Icon
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
228 Solution Ultima 844/862/880 Installation Manual
System Options 2
LOCATION 437 0
Option Description
1
Codepad Panic To Be Silent
2
Codepad Fire To Be Silent
4
Codepad Medical To Be Silent
8
Access Denied To Be Silent
1
2
4
8
Table 140: System Options 2
Codepad Panic To Be Silent
If this option has been selected, a codepad panic alarm or radio remote panic alarm will not operate
the horn speaker, the bell or the strobe outputs. If this option is not selected, all three outputs will
operate after a codepad panic alarm has been activated when the
1and 3 buttons or the and
buttons on the remote codepad are pressed simultaneously. Selecting this option does not effect
the operation of the communication dialler.
If you wish to disable the reporting of the codepad panic alarm, program “LOCATION 349 - 350” on
page 190 as zero.
Codepad Fire To Be Silent
If this option has been selected, a codepad fire alarm will not operate the horn speaker, the bell or the
strobe outputs. If this option is not selected, all three outputs will operate after a codepad fire alarm
has been activated when the
4 and 6 buttons on the remote codepad are pressed simultaneously.
Selecting this option does not effect the operation of the communication dialler.
If you wish to disable the reporting of the codepad fire alarm, program “LOCATION 351 - 352” on
page 191 as zero.
Codepad Medical To Be Silent
If this option has been selected, a codepad medical alarm will not operate the horn speaker, the bell or
the strobe outputs. If this option is not selected, all three outputs will operate after a codepad fire
alarm has been activated when the
7 and 9 buttons on the remote codepad are pressed
simultaneously. Selecting this option does not effect the operation of the communication dialler.
If you wish to disable the reporting of the codepad medical alarm, program “LOCATION 353 - 354”
on page 191 as zero.
Access Denied To Be Silent
If this option has been selected, a codepad tamper alarm will not operate the horn speaker, bell or the
strobe outputs. If this option is not selected, all three outputs will operate after a codepad tamper
alarm has occurred.
Refer to "LOCATION 368" on page 195 to set the number of invalid code retries before an alarm
condition occurs. Selecting this option does not effect the operation of the communication dialler. If
you wish to disable the reporting of access denied reports program “LOCATION 369 - 370” as zero.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited