Loading...
232 Solution Ultima 844/862/880 Installation Manual
Consumer Options 2
LOCATION 441 2
Option Description
1
Codepad Display Extinguish After 60 Seconds
2
Single Button Arming Allowed (AWAY Mode, STAY Mode 1 & 2)
4
Single Button Disarming Allowed (STAY Mode 1 & 2)
8
Alarm Memory Reset On Disarm
1
2
4
8
Table 144: Consumer Options 2
Codepad Display Extinguish After 60 Seconds
If this option has been selected, all indicators on the remote codepad display will extinguish if a
button is not pressed for 60 seconds. The indicators will illuminate when there is an alarm (except a
silent alarm), when a button is pressed on the codepad, when the AC mains fail beeps, or if the entry
timer has been activated.
Single Button Arming Allowed (AWAY Mode, STAY Mode 1 & 2)
If this option has been selected, the hold down functions for arming in AWAY Mode, STAY Mode 1
and STAY Mode 2 will be functional. Refer to Hold Down Functions on page 93 for more
information.
Single Button Disarming Allowed (STAY Mode 1 & 2)
This option will only operate when Option 2 in this location has also been selected. This option will
allow hold down functions for disarming from STAY Mode 1 and STAY Mode 2. Refer to Hold
Down Functions on page 93 for more information.
Alarm Memory Reset On Disarm
This option allows the memory of alarm events to be cleared from the remote codepad when the
system has been disarmed. If this option has not been selected, the system will need to be armed and
disarmed again to clear alarm memory from the remote codepad.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited

Table of Contents