System Operations 53
Fault Descriptions
1
System Fault
A system fault will only display when any of the following faults occur. After entering fault analysis
mode, holding down button
1will determine which of the following faults have occurred.
Low Battery
A low battery fault will register when the system detects a low capacity back-up battery. The system
automatically performs a battery test every 4 hours and also every time you arm the system.
Date and Time
The date and time fault will register every time the system has been powered down. This type of fault
will not cause the FAULT indicator to display on the codepad unless your installer has programmed
the automatic arming time. To program the date and time, refer to page 89.
RF Receiver Fail
The RF receiver fault will register once the system has detected that the RF wireless receiver unit has
registered RF Jamming, the RF wireless receiver has been disconnected from the control panel or has
failed, or the RF receiver’s cover tamper switch has been activated.
Horn Speaker
This fault will register when the system detects that the horn speaker has been disconnected. This
fault will clear once the horn speaker has been reconnected. Your installer will need to program the
system for this feature to operate.
Telephone Line Fail
A telephone line fault will register when the system detects that the telephone line has been
disconnected from the control panel. Your installer will need to program the system for this feature to
operate.
E2 Fault
An E2 fault will register when the system detects an internal checksum error. Contact your installer as
soon as this fault is displayed.
Fuse Fail
This fault will occur when either of the two 1 Amp fuses has blown. Contact your installer as soon as
this fault is displayed.
2
RF Low Battery
This fault will occur when any wireless zone (1 – 8) has reported a low battery condition to the control
panel. Whilst you are in fault analysis mode, holding down button
2 until two beeps are heard will
display which zone has reported the RF Low Battery fault.