Zone Information 179
Zone Options 2
When programming this location, you will notice that there are four options per location. You may
select one, two, three or all four of these options, however, only one number needs to be programmed.
This number is calculated by adding the option bit numbers together. Program a seven (7) if you
require options 1, 2 and 4 simultaneously (i.e.. 1 + 2 + 4 = 7).
Option Description
1
Isolate In STAY Mode 1
2
Zone Isolation Allowed
4
Forced Arming Allowed
8
Zone Restore Report
1
2
4
8
Table 84: Zone Options 2
Isolate In STAY Mode 1
If this option has been selected, it will allow the zone to be automatically isolated when the system has
been armed in STAY Mode 1.
If this option is not selected, when the system has been armed in STAY Mode 1, the zone will activate
an alarm when triggered as it normally would in AWAY Mode.
Refer to Entry Guard Timer For STAY Mode on page 217 if you wish to program a global entry time
for ALL zones except for 24-hour zone types when armed in STAY Mode 1 (i.e.. The entry guard
timer will override the delay time programmed for a delay zone). If the entry guard timer has been
programmed as "0" each zone will act as per its programmed zone type.
Refer to Arming The System In STAY Mode 1 on page 42 for more information.
Zone Isolation Allowed
If this option has been selected, it will allow a user to isolate the zone before arming the system. If
this option is not selected, the zone can not be manually isolated. When a zone has been manually
isolated, a zone bypass report will be sent. Refer to Isolating Zones on page 48 for more information.
When isolating 24-hour zone types, the 24-hour zone will automatically send a zone bypass report at
the time the zone is selected to be isolated. All non 24-hour zone types will only send a bypass report
at the time the system is armed.
If you require the system not to report zone bypass reports, program “LOCATION 329 - 330” on page
185 as zeros.
Forced Arming Allowed
If this option has been selected, it will allow the system to be armed with the zone unsealed. If this
option is not selected, the system will not allow the user code holder to arm the system until the zone
in question has been sealed or manually isolated. Refer to Isolating Zones on page 48 for more
information.
Zone Restore Report
If this option has been selected, the zone will send restore reports as soon as the zone has restored. If
this option has not been selected, the zone will not send restore reports after the zone has restored.
If a non 24-hour zone has not restored at the time the system is disarmed, the system will
automatically send a zone restore report for that zone. All 24-hour zone types will only a send zone
restore report at the time the zone has restored.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC