When the user commits to a conguraon, the CLI rst validates the conguraon and, if a problem exists,
indicates what the problem is. For example, if an idener is missing or a value is out of range, a message
indicates where the errors are.
Example:
% set eqpt shelf 1 slot 0 cardType BDT3-T300 subslot 0 port C11
pluggableInterfaceType QSFP28 admin-status up
[ok]
[edit]
% commit
Aborted: 'eqpt shelf 1 slot 0 subslot 0 port C11' : pluggable/port/card
mismatch
[error]
[edit]
%