Step 27
In the /equipment:eqpt/shelf(n)/slot(x)/subslot(0)/port("Cz") tab, select up from the admin-status dropdown
list.
Step 28
Select Client from the pluggableInterfaceType dropdown list.
Step 29
Press Commit to commit the changes.
Step 30
Close the /equipment:eqpt/shelf(n)/slot(x)/subslot(0)/port("Cz") tab.
Step 31
Repeat Step 24 through Step 30 for each client port to be provisioned.
Step 32
If a second slot is provisioned, repeat Step 10 through Step 31 to provision the edge and client ports for the
second slot.
Step 33
Close the following tabs:
/equipment:eqpt/shelf, /equipment:eqpt/shelf(n)
/equipment:eqpt/shelf(n)/slot("x")
/equipment:eqpt/shelf(n)/slot("x")/subslot("0")
Connue with the next task.
7.12.2
Provision L110 Tributary Blade OCH Interfaces
Step 1
Provision an OCH interface on a PIL1-3PS2 PIU.
Command:
% set interfaces interface och-3/1/0/C1 type opticalChannel enabled och
Step 2
Repeat Step 1 for each OCH interface (1…16) to be provisioned.
This task is complete.