8.1.5
Retrieve Alarms and PMs
Prerequisite:
â– User must be logged on to the Main blade.
The following CLI command examples may be useful in locang or narrowing the scope of a problem.
Step 1
Retrieve the alarms.
Command:
> show alarms alarm-list
Step 2
Retrieve the PM for the network port.
Command:
> show pm-equipment shelf 1 slot 1 subslot 0 port C1 pm-record opticalPowerReceive
time-period-index 15-min 0
Step 3
Retrieve the PM for the client port.
Command:
> show pm-equipment shelf 1 slot 0 subslot 0 port C1 pm-oper-data
opticalPowerReceive pm-time-period-index 15-min
Step 4
Retrieve the interface PM.
Command:
> show pm-interfaces interface eth-1/0/0/E-SC-E1 pm-oper-data codingViolation pm-
time-period-index 1-day
✓ This task is complete.
8.1.6
Alarms and Conditions
This secon describes alarms and condion codes and includes the following types of informaon:
■Enty type
■Severity (warning, minor, major, or crical)
■Service aected (service-aecng or non–service-aecng)
System Maintenance
Trouble Clearing
294
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only