thresholdCrossingAlertOscOpticalReceivePowerTooLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The opcal receive power at the OSC port is
below the threshold level.
Probable Cause Suggested Correcve Acon
Opcal OSC receive power is too low. 1. Verify that the appropriate transmier is installed at
the far end.
2. Verify that the transmit output level at the far end is
within specicaons. Replace the transmier if the
level is too low.
3. Clean ber connecons in the path.
thresholdCrossingAlertOscOpticalTransmitPowerTooHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The opcal transmit power at the OSC port
is above the threshold level.
Probable Cause Suggested Correcve Acon
Opcal OSC transmier power is too high. Replace the blade if necessary.
thresholdCrossingAlertOscOpticalTransmitPowerTooLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The opcal transmit power at the OSC port
is below the threshold level.
Probable Cause Suggested Correcve Acon
Opcal OSC transmier power is too low. 1. Verify that the transmit output level is within
specicaons.
2. Replace the blade if necessary.
System Maintenance
Trouble Clearing
338