thresholdCrossingAlertOscOpticalReceivePowerTooLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The opcal receive power at the OSC port is
below the threshold level.
Probable Cause Suggested Correcve Acon
Opcal OSC receive power is too low. 1. Verify that the appropriate transmier is installed at
the far end.
2. Verify that the transmit output level at the far end is
within specicaons. Replace the transmier if the
level is too low.
3. Clean ber connecons in the path.
thresholdCrossingAlertOscOpticalTransmitPowerTooHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The opcal transmit power at the OSC port
is above the threshold level.
Probable Cause Suggested Correcve Acon
Opcal OSC transmier power is too high. Replace the blade if necessary.
thresholdCrossingAlertOscOpticalTransmitPowerTooLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The opcal transmit power at the OSC port
is below the threshold level.
Probable Cause Suggested Correcve Acon
Opcal OSC transmier power is too low. 1. Verify that the transmit output level is within
specicaons.
2. Replace the blade if necessary.