equipmentFault
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
AC00-F011 minor non–service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
Either FAN1 or FAN2 has failed. Replace the failed Fan unit as soon as possible.
AC00-F011 crical service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
Both FAN1 and FAN2 have failed. Replace the failed Fan units as soon as possible.
BDL1-3B11, BDL1-3R11 minor non–service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A BDL1-3B11 or BDL1-3R11 blade has failed. Replace the failed blade as soon as possible.
BDL1-3B11, BDL1-3R11 crical service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A BDL1-3B11 or BDL1-3R11 blade has failed. Replace the failed blade as soon as possible.
PIL1-3PS2 minor non–service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A PIL1-3PS2 PIU has failed. Replace the failed PIU as soon as possible.
PIL1-3PS2 crical service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A PIL1-3PS2 has failed. Replace the failed PIU as soon as possible.
1GEX SFP minor non–service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A 1GEX SFP module has failed. Replace the failed SFP module as soon as possible.