7.16
Interoperability with L130 Blade
The interoperability between L100 and L130 Blades is automac. Turn up both the L100 and L130 Blades
normally and connect the bers between the L100 and L130 Blades. The connecon between the blades is
autoprovisioned.
Note: When L100 Blade supports interoperability with L130 Release 19.1.1, the span supported between L130
and L100 Blades must be Raman ampliers (with L160 Blade).
Note: OSNR seng must be enabled in L100 Blade to support interoperability with L130 Blade.
Note: When L100 Blade supports interoperability with L130 Blade, the OSNR seng on the L100 must be set to
enable. Otherwise, an outstanding osnrModeMismatch alarm is raised on the L100 Blade.
ROADM Turn-Up and Operations
Interoperability with L130 Blade
282
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only