7.16
Interoperability with L130 Blade
The interoperability between L100 and L130 Blades is automac. Turn up both the L100 and L130 Blades
normally and connect the bers between the L100 and L130 Blades. The connecon between the blades is
autoprovisioned.
Note: When L100 Blade supports interoperability with L130 Release 19.1.1, the span supported between L130
and L100 Blades must be Raman ampliers (with L160 Blade).
Note: OSNR seng must be enabled in L100 Blade to support interoperability with L130 Blade.
Note: When L100 Blade supports interoperability with L130 Blade, the OSNR seng on the L100 must be set to
enable. Otherwise, an outstanding osnrModeMismatch alarm is raised on the L100 Blade.
ROADM Turn-Up and Operations
Interoperability with L130 Blade
282
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only