Loading...
Direcon (transmit, receive, or not applicable [n/a])
Locaon (near end, far end, or n/a)
Descripon
Probable causes
Suggested correcve acons
The following abbreviaons are used in the alarms and condion code tables in this secon.
NSA Non–service-aecng
SA Service-aecng
RX Receive
TX Transmit
FEND Far end
NEND Near end
n/a Not applicable
administrativeDown
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PIL1-3PS2, PIL1-3PS3, AC00-
F011
warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the PIU or Fan
unit is set to DOWN.
Change the administrave state to UP.
BDL1-3B11, BDL1-3J11,
BDL1-3R11
warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the blade is set
to DOWN.
Change the administrave state to UP.
1GEX warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the SFP module
is set to DOWN.
Change the administrave state to UP.