Enty Type Severity
Service
Aected
Direcon Locaon Descripon
1GEBT minor non–service-
aecng
transmit NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEX interface is too low.
Check the opcal transmit power at the indicated interface.
1GEBT minor non–service-
aecng
receive NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
1GEX interface is too low.
Check the opcal receive power at the indicated interface.
1GEBT crical service-
aecng
transmit NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEX interface is too low.
Check the opcal transmit power at the indicated interface.
1GEBT crical service-
aecng
receive NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
1GEX interface is too low.
Check the opcal receive power at the indicated interface.
powerProblemA
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
BDL1-3B11, BDL1-3R11 major non–service-
aecng
n/a NEND Power Input Fail: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■The A power feed on the –48 V DC
power adapter has failed.
■The –48 V DC A power feed has failed at
the source.
1. Check the power connecons on the A power feed on
the –48 V DC power adapter and/or the –48 V DC
power source.
2. Check the input voltage at the A power feed on the –
48 V DC power adapter.
System Maintenance
Trouble Clearing
330
Release 19.1.1 · Issue 1.1, May 2021