oscPowerOutOfSpecicationLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
Port (Edge) crical service-
aecng
receive NEND OPROSC Power Out of Specicaon–Low:
TYPE = <unit type>
Probable Cause Suggested Correcve Acon
Opcal Receive Power OSC is too low. 1. Verify that the appropriate transmier is installed at
the far end.
2. Verify that the transmit output level is within
specicaons.
3. Install an appropriate opcal aenuator in the line at
the receiver.
osnrModeMismatch
Enty Type Severity
Service
Aect
Direcon Locaon Descripon
OTS major service-
aecng
receive NEND OSNR Mode Mismatch
Probable Cause Suggested Correcve Acon
A mismatch exists between local NE and
remote NE values for the OSNR
enhancement seng.
Verify the provisioning of the OSNR enhancement seng
between the two NEs.
otsSpanlossPowerOutOfSpecicationHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
ots crical service-
aecng
receive NEND SPANLOSS Out of Specicaon–High
Probable Cause Suggested Correcve Acon
■ The threshold level has been improperly
set.
■ Aenuaon on exisng span has
increased.
1. Verify the proper threshold levels with local standards.
2. If needed, reset the PM threshold to correct.
3. Follow local pracces to check the physical
characteriscs of the exisng span.
System Maintenance
Trouble Clearing
321
Release 19.1.1 · Issue 1.1, May 2021