thresholdCrossingAlertSeverelyErroredSeconds
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
Ether OSC (BDL1-3R11) warning non–service-
aecng
receive NEND The threshold for severely errored seconds
has been crossed.
Probable Cause Suggested Correcve Acon
■ Opcal path problems exist between
the upstream node and the near end.
■ The blade has failed.
1. Check the opcal output level at the upstream
transmier.
2. Check the opcal receive level at the input to the local
BDL1-3R11 blade.
3. Replace the blade.
thresholdCrossingAlertSpanlossVariationTooHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The span loss variaon is above the
threshold level.
Probable Cause Suggested Correcve Acon
■ The threshold level is improperly set.
■ Aenuaon on the exisng span has
increased.
1. Verify the proper threshold levels with local standards.
If needed, reset the PM threshold to correct.
2. Follow local pracces to check the physical
characteriscs of the exisng span.
thresholdCrossingAlertSpanlossVariationTooLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The span loss variaon is below the
threshold level.
Probable Cause Suggested Correcve Acon
■ The threshold level is improperly set.
■ Aenuaon on the exisng span has
decreased.
1. Verify the proper threshold levels with local standards.
If needed, reset the PM threshold to correct.
2. Follow local pracces to check the physical
characteriscs of the exisng span.