7.4
Provision L100 Main Blade OTS/OMS/OCH Interfaces
Step 1
Enable the Opcal Transmission Secon (OTS) for the Main L100 Blade.
Command:
% set interfaces interface ots-1/0/0/E1 type opticalTransport ots degree-number 1
operation-mode ope-mode-full-spec admin-status up
Step 2
Provision the Opcal Mulplex Secon (OMS) and postoutadj value for the Main L100 Blade.
Command:
% set interfaces interface ots-1/0/0/E1 ots oms admin-status up postoutadj <value>
Note: The postoutadj design value for the network is calculated during network design and planning process.
Postoutadj value range is within –15.0…0.0 dB. The default value is 0.0 dB. Seng should be implemented in
inial system turn-up.
Contact Fujitsu Support Center for assistance on the postoutadj value.
Step 3
Enable the OTS for a tributary L100 Blade.
Command:
% set interfaces interface ots-2/0/0/E1 type opticalTransport ots degree-number 2
operation-mode ope-mode-full-spec admin-status up
Note: Repeat this step to enable the OTS for each tributary L100 Blade.
Step 4
Provision the OMS and a postoutadj value for a tributary L100 Blade.
Command:
% set interfaces interface ots-2/0/0/E1 ots oms admin-status up postoutadj <value>
Note: Repeat this step to enable the OMS for each tributary L100 Blade.
Step 5
Provision an OCH interface.
Command:
% set interfaces interface ots-2/0/0/E1 ots oms och 1 admin-status up center-
frequency 196.1
Note: Repeat this step for each OCH interface to be provisioned.
Note: With exible grid enabled, the slot width can be provisioned for a value between 37.5 to 100 GHz (in 12.5
GHz increments) with a maximum of 128 channels.