9.2
Remove SFP Module
The following links lead to related informaon:
Install SFP Module
Danger: Never look into the end of a ber-opc cable. Permanent eye damage or blindness can occur very
quickly if the laser light is present. Follow local safety precauons regarding ber.
Danger: Never handle exposed ber with bare hands or touch it to bare skin. Fiber fragments can enter
the skin and are dicult to detect and remove. Follow local safety precauons regarding ber.
Cauon: Unplugging a SFP module can be trac-aecng. Make sure trac is not dependent on the
module before removing.
Step 1
Locate the SFP module to be removed.
Step 2
Inspect the ber connecons to (if any) the module to be removed. Verify that each ber is clearly marked or
labeled to idenfy the correct connecon locaon.
Note: Fiber marking or labeling depends on local pracce.
Step 3
Is each ber clearly marked to show its corresponding connector?
If YES:
Connue with next step.
If NO:
Mark or label bers according to local pracce and connue with next step.
Step 4
Disconnect the ber-opc cables from the module to be removed.
Cauon
: Do not remove the wrong ber connecons. Removing a ber connecon that is in use disrupts
service.
Step 5
Li the release lever on the module to release it from the PIU, and slowly and carefully pull module straight out.
Equipment Removal
Remove SFP Module
425
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only