databaseLockedSoftwareUpgradeInProgress
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
COM warning non–service-
aecng
n/a NEND Database System Locked; Soware Upgrade
In Progress
Probable Cause Suggested Correcve Acon
The database is locked due to a soware
upgrade in progress.
No acon is required. The condion clears when the
soware upgrade completes.
databaseVersionMismatch
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
COM major non–service-
aecng
n/a NEND Database Version Mismatch
Probable Cause Suggested Correcve Acon
The database system of a tributary blade
does not match the database system read
from the Main blade.
1. If execung a new turn-up, perform a WARM reset on
the tributary blade.
2. If the condion does not clear or if the tributary blade
is carrying trac, call Fujitsu for technical assistance at
1-800-USE-FTAC (1-800-873-3822).
equipmentCurrExceededFeed
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
BDL1-3B11, BDL1-3R11 crical non–service-
aecng
n/a NEND The current drawn is greater than 80
percent of the fuse rang.
Probable Cause Suggested Correcve Acon
Current drawn is greater than 80 percent of
unit fuse feed rang.
Increase the rang for the fuse feed.
System Maintenance
Trouble Clearing
301
Release 19.1.1 · Issue 1.1, May 2021