oscControlFailure
Enty Type Severity
Service
Aect
Direcon Locaon Descripon
OTS non-alarmed non–service-
aecng
receive NEND OSC Control Fail
Probable Cause Suggested Correcve Acon
The OSC communicaon is incorrect. Check the local receive and upstream transmit condion.
oscModeMismatch
Enty Type Severity
Service
Aect
Direcon Locaon Descripon
100ME major service-
aecng
receive NEND Dierent OSC Mode is automacally set by
the system on the span with L160 Raman
blade provision or not.
Probable Cause Suggested Correcve Acon
L160 Raman blade is not provisioned on
both NEs on the span.
Verify that the L160 Raman blade provisioning on both NEs
on the span is correct.
oscPowerOutOfSpecicationHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
Port (Edge) crical service-
aecng
receive NEND OPROSC Power Out of Specicaon–High:
TYPE = <unit type>
Probable Cause Suggested Correcve Acon
Opcal Receive Power OSC is too high. 1. Verify that the appropriate transmier is installed at
the far end.
2. Verify that the transmit output level is within
specicaons.
3. Install an appropriate opcal aenuator in the line at
the receiver.
System Maintenance
Trouble Clearing
320
Release 19.1.1 · Issue 1.1, May 2021