7.2
Enable OSNR for Main Blade
Note: By default, the OSNR is disabled for a Main blade.
Step 1
Enter congure mode.
Command:
> configure
Step 2
Enable OSNR for all blades in NE.
Note: OSNR seng must be enabled in L100 Blade to support interoperability with L130 Blade.
Command:
% set wdmcfg osnr enable
Step 3
Save the changes.
Command:
% commit
Step 4
Verify OSNR sengs.
Command:
% show wdmcfg osnr
Output:
osnr enable
This task is complete.