thresholdCrossingAlertOpticalReceivePowerTooLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
EQPT warning non–service-
aecng
receive NEND The opcal receive power level is above the
threshold on one of the following ports:
■ For BDL1-3R11:
• E-SC-E1
• F-SC-E1
• LCN1…4
■ For BDL1-3B11: LCN1…4
Probable Cause Suggested Correcve Acon
Opcal receive power is too low. 1. Verify that the appropriate transmier is installed at
the far end.
2. Verify that the transmit output level is within
specicaons at the far end.
3. Replace the transmier at the far end if the level is too
low.
4. Clean the ber connecons in the path.
thresholdCrossingAlertOpticalTransmitPowerTooHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
EQPT warning non–service-
aecng
receive NEND The opcal receive power level is above the
threshold on one of the following ports:
■ For BDL1-3R11:
• E-SC-E1
• F-SC-E1
• LCN1…4
■ For BDL1-3B11: LCN1…4
Probable Cause Suggested Correcve Acon
Opcal receive power is too high. 1. Verify that the transmier output level is within
specicaons.
2. Replace the blade if necessary.