equipmentShelfProvisioningMode
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
COM warning non–service-
aecng
n/a NEND The shelf provisioning mode is set to an
incorrect value.
Probable Cause Suggested Correcve Acon
The shelf provisioning mode is incorrect. 1. If the blade is set to factory defaults in a new turn-up,
iniate a WARM reset to make this blade the Main
blade.
2. For a tributary blade in a new turn-up, change the
shelf type to TRIB.
3. If the NE is carrying trac and the shelf provision
command is sent by accident, cancel the shelf
provisioning command to clear the condion.
equipmentWarmup
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
BDL1-3R11 warning non–service-
aecng
n/a NEND Equipment Warm-Up: TYPE = <unit type>
Probable Cause Suggested Correcve Acon
The blade is in a warm-up condion
following power-up.
No acon is required. The condion appears aer the
facility is provisioned, and the condion clears when the
unit achieves the desired output wavelength.
PIL1-3PS2 warning non–service-
aecng
n/a NEND Equipment Warm-Up: TYPE = <unit type>
Probable Cause Suggested Correcve Acon
The PIU is in a warm-up condion following
inseron.
No acon is required. The condion appears aer the
facility is provisioned, and the condion clears when the
unit achieves the desired output wavelength.