Enty Type Severity
Service
Aected
Direcon Locaon Descripon
100ME minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
100ME crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
155M minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment.
155M crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
1GEBT minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
1GEBT crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
System Maintenance
Trouble Clearing
309
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu 1FINITY L100 and is the answer not in the manual?

Fujitsu 1FINITY L100 Specifications

General IconGeneral
BrandFujitsu
Model1FINITY L100
CategoryServer
LanguageEnglish

Related product manuals