EasyManua.ls Logo

Fujitsu 1FINITY L100 - Page 309

Fujitsu 1FINITY L100
473 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
100ME minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
100ME crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
155M minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment.
155M crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
1GEBT minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
1GEBT crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
System Maintenance
Trouble Clearing
309
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only

Table of Contents

Related product manuals