Enty Type Severity
Service
Aected
Direcon Locaon Descripon
100ME minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
100ME crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
155M minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment.
155M crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
1GEBT minor non–service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.
1GEBT crical service-
aecng
n/a NEND Equipment Removed: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
The SFP module is not properly seated or
has been removed and has an interface
provisioned on it.
Reseat or replace the SFP module. If a SFP module is not
required in the port generang the alarm, the alarm can be
cleared by deleng the equipment port.