rmwareVersionMismatch
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
BDL1-3B11, BDL1-3R11 minor service-
aecng
n/a NEND Firmware Version Mismatch: TYPE = <unit
type>
Probable Cause Suggested Correcve Acon
The FW on the tributary blade specied in
the alarm is not compable with the system
soware.
Perform the FW upgrade procedure on the indicated blade.
BDL1-3B11, BDL1-3R11 major service-
aecng
n/a NEND Firmware Version Mismatch: TYPE = <unit
type>
Probable Cause Suggested Correcve Acon
The FW on the tributary blade specied in
the alarm is not compable with the system
soware.
Perform the FW upgrade procedure on the indicated blade.
forwardDefectIndication
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
och warning service-
aecng
receive NEND Forward Defect Indicaon
Probable Cause Suggested Correcve Acon
An OCH signal failure, for example, a WDM
LOS, has occurred in the upstream direcon.
Clear the upstream WDM transmit signal failure.
Cauon: The OSC must be acve for trac to be restored.
A failure of the OSC may keep trac from recovering on a
span.