trailTraceMismatch
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
OC3 OSC (BDL1-3R11) major non–service-
aecng
receive NEND A mismatch exists on the trail trace
idener.
Probable Cause Suggested Correcve Acon
The Receive Source Access Point Idener
(RCVSAPI) is dierent from Expected Source
Access Point Idener (EXPSAPI), the
Receive Desnaon Access Point Idener
(RCVDAPI) is dierent from Expected
Desnaon Access Point Idener
(EXPDAPI), or both condions exist.
1. Ensure that the local EXPSAPI, EXPDAPI, or both are set
correctly to match the ones transmied from the far
end.
2. Ensure that the far-end transming Source Access
Point Idener (SAPI) and Desnaon Access Point
Idener (DAPI) match the local EXPSAPI and/or
EXPDAPI.
3. If the problem persists, verify the ber connecons for
add and drop connecons.
unequippedIndication
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
OC3 OSC (BDL1-3R11) major service-
aecng
receive NEND An unequipped indicaon is received.
Probable Cause Suggested Correcve Acon
A WCH is not provisioned or equipped. 1. Verify that the correct blade type is installed.
2. Check the channel provisioning and correct if
necessary.
Cauon: The OSC must be acve for trac to be restored.
A failure of the OSC may keep trac from recovering on a
span.
ztpBootFailure
Enty Type Severity
Service
Aect
Direcon Locaon Descripon
COM major non–service-
aecng
n/a NEND ZTP Boot failure.
Probable Cause Suggested Correcve Acon
ZTP-Boot retries auto-upgrade aer 5
minutes.
No acon is required. ZTP-Boot retries auto-upgrade aer 5
minutes.
Note: This alarms clears at the end of 5 minutes.