thresholdCrossingAlertOpticalTransmitPowerTooLow
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
EQPT warning non–service-
aecng
receive NEND The opcal receive power level is above the
threshold on one of the following ports:
■ For BDL1-3R11:
• E-SC-E1
• F-SC-E1
• LCN1…4
■ For BDL1-3B11: LCN1…4
Probable Cause Suggested Correcve Acon
Opcal receive power is too low. 1. Verify that the transmier output level is within
specicaons.
2. Clean the port and the ber aached to it.
3. Replace the blade if necessary.
thresholdCrossingAlertOscOpticalReceivePowerTooHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
PORT=E1 (BDL1-3R11) warning non–service-
aecng
receive NEND The opcal receive power at the OSC port is
above the threshold level.
Probable Cause Suggested Correcve Acon
Opcal OSC receive power is too high. 1. Verify that the appropriate transmier is installed at
the far end.
2. Verify that the transmit output level at the far end is
within specicaons.
3. Install an appropriate opcal aenuator at the
receiver.
System Maintenance
Trouble Clearing
337
Release 19.1.1 · Issue 1.1, May 2021