postBlockAutoPowerReduction
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
oms warning non–service-
aecng
n/a NEND Post Block Automac Power Reducon:
TYPE = <unit type>
Probable Cause Suggested Correcve Acon
APR has been triggered for the amplier. Check the ber connecons to/from the PIU.
postBlockAutoShutoffDisabled
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
oms warning non–service-
aecng
n/a NEND Post Block Laser Safety Override Acve:
TYPE = <unit type>
Probable Cause Suggested Correcve Acon
A command is issued to forcefully turn on
the laser.
None
postBlockManualLaserShutdown
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
oms warning non–service-
aecng
n/a NEND Post Block Manual Laser Shutdown: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The user has changed laser shutdown to
manual.
Change laser shutdown to automac.
System Maintenance
Trouble Clearing
324
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only