5.2
Set Up Main Blade (Initial)
Warning: Aer the blade is powered up, power down within 15 minutes causes database corrupon,
which leads to blade start-up failure and requires a return to factory for reprogramming.
Step 1
Apply power to the Main blade.
Step 2
Log on the blade using the LMP as described in Log On.
Step 3
Retrieve the alarms.
Command:
> show alarms alarm-list
Step 4
Check if the shelfProvisioningMode alarm is present.
If YES:
Connue with next step.
If NO:
This procedure is complete.
Step 5
Execute the Main blade setup.
Command:
> request set-shelfmode shelfid <shelf-id˃ shelfrole <shelf-role˃
Table 43
Input Parameter
Parameter Value Descripon
shelf-id <1> Shelf value for the blade
shelf-role <MAIN> Name of shelf role
Command Example:
> request set-shelfmode shelfid 1 shelfrole MAIN
Step 6
When the queson "Really want to do this?" appears, enter "yes".
Initial System Turn Up
Set Up Main Blade (Initial)
162
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only