EasyManua.ls Logo

Fujitsu 1FINITY L100 - Provision Cross-Connects

Fujitsu 1FINITY L100
473 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.10
Provision Cross-Connects
Step 1
Provision a DROP cross-connect from an OCH on an edge port of an L100 Blade to a client port on a PIL1-3PS2
PIU.
Command:
% set fabric och-connection XCON-DROP src-if ots-2/0/0/E1 src-och 1 dst-if
och-3/1/0/C1
Step 2
Provision a ADD cross-connect from a client port on a PIL1-3PS2 to an OCH on an edge port of an L100 Blade.
Command:
% set fabric och-connection XCON-ADD src-if och-3/1/0/C1 dst-if ots-2/0/0/E1 dst-
och 1
Step 3
Provision pass-through cross-connects between two CD ROADM degrees.
Commands:
% set fabric och-connection XCON-PASS-1 src-if ots-1/0/0/E1 src-och 2 dst-if
ots-2/0/0/E1 dst-och 2
% set fabric och-connection XCON-PASS-2 src-if ots-2/0/0/E1 src-och 2 dst-if
ots-1/0/0/E1 dst-och 2
This task is complete.