Enty Type Severity
Service
Aected
Direcon Locaon Descripon
1GEX SFP crical service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A 1GEX SFP module has failed. Replace the failed SFP module as soon as possible.
100ME SFP minor non–service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A 100ME SFP module has failed. Replace the failed SFP module as soon as possible.
100ME SFP crical service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A 100ME SFP module has failed. Replace the failed SFP module as soon as possible.
1GEBT SFP minor non–service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A 1GEBT SFP module has failed. Replace the failed SFP module as soon as possible.
1GEBT SFP crical service-
aecng
n/a NEND Equipment Fault: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
A 1GEBT SFP module has failed. Replace the failed SFP module as soon as possible.
equipmentInterConnectFailure
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
major non–service-
aecng
n/a NEND Interblade communicaon Link Failure:
TYPE = <unit type>
Probable Cause Suggested Correcve Acon
A failure has occurred in the interblade
communicaon links that connect the
blades.
1. Check for loose connectors on each interblade
communicaon link.
2. Check for and replace any damaged interblade
communicaon cables.
System Maintenance
Trouble Clearing
303
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only