Enty Type Severity
Service
Aected
Direcon Locaon Descripon
100ME warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the SFP module
is set to DOWN.
Change the administrave state to UP.
1GEBT warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the SFP module
is set to DOWN.
Change the administrave state to UP.
155M warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the SFP module
is set to DOWN.
Change the administrave state to UP.
ots warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the OTS enty is
set to DOWN.
Change the administrave state to UP.
oms warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the OMS enty
is set to DOWN.
Change the administrave state to UP.
och warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the OCH enty is
set to DOWN.
Change the administrave state to UP.