Step 2
Provision a ADD cross-connect from a client port on a PIL1-3PS2 to an OCH on an edge port of an L100 Blade.
Command:
% set fabric och-connection XCON-ADD src-if och-3/1/0/C1 dst-if ots-2/0/0/E1 dst-
och 1
Step 3
Provision pass-through cross-connects between two CD ROADM degrees.
Commands:
% set fabric och-connection XCON-PASS-1 src-if ots-1/0/0/E1 src-och 2 dst-if
ots-2/0/0/E1 dst-och 2
% set fabric och-connection XCON-PASS-2 src-if ots-2/0/0/E1 src-och 2 dst-if
ots-1/0/0/E1 dst-och 2
This task is complete.