Table 48 (Cont.)
LED and Condion
LED Color Condion
E-SC-E1 (on SFP module) Green Link up (with or without acve data communicaon)
Red OSC LOS
OSC fault
OSC link down
One of the following alarms is present:
■ equipmentRemoved
■ powerOutOfSpecicaonHigh
■ powerOutOfSpecicaonLow
Blinking red MEA
FAN1, FAN2 Green No error condion (normal operaon)
Red Error condion (fan failed, fan removed)
Blinking red Fan mismatch
O Power o
F-SC-E1 Green Link up (without data communicaon)
Blinking green Link up under data communicaon
Red OSC LOS
OSC fault
OSC link down
Blinking red MEA
Enty Type Green Link up (with or without acve data communicaon)
Red Error condion (link down, module failure, module removal)
One of the following alarms is present:
■ LOS (eth)
■ POS (port)
Blinking red MEA
OSC Green Incoming opcal signal operang normally
Red Input port down
One of the following alarms is present:
■ powerOutOfSpecicaonHigh
■ powerOutOfSpecicaonLow
O Power o
System Maintenance
Trouble Clearing
286