Table 48 (Cont.)
LED and Condion
LED Color Condion
E-SC-E1 (on SFP module) Green Link up (with or without acve data communicaon)
Red OSC LOS
OSC fault
OSC link down
One of the following alarms is present:
â–  equipmentRemoved
■ powerOutOfSpecicaonHigh
■ powerOutOfSpecicaonLow
Blinking red MEA
FAN1, FAN2 Green No error condion (normal operaon)
Red Error condion (fan failed, fan removed)
Blinking red Fan mismatch
O Power o
F-SC-E1 Green Link up (without data communicaon)
Blinking green Link up under data communicaon
Red OSC LOS
OSC fault
OSC link down
Blinking red MEA
Enty Type Green Link up (with or without acve data communicaon)
Red Error condion (link down, module failure, module removal)
One of the following alarms is present:
â–  LOS (eth)
â–  POS (port)
Blinking red MEA
OSC Green Incoming opcal signal operang normally
Red Input port down
One of the following alarms is present:
■ powerOutOfSpecicaonHigh
■ powerOutOfSpecicaonLow
O Power o
System Maintenance
Trouble Clearing
286
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu 1FINITY L100 and is the answer not in the manual?

Fujitsu 1FINITY L100 Specifications

General IconGeneral
BrandFujitsu
Model1FINITY L100
CategoryServer
LanguageEnglish

Related product manuals