Table 56 (Cont.)
Port PM Counters (BDL1-3R11)
Counter Enty Type
Fiber Type
(Capacity)
PM Type Locaon Direcon
Valid Operang
Range
spanloss Port (E1)
TrueWave®
(Full)
TrueWave-C
(Full)
Metered NEND RX 0.0…33.0
(warm-up)
0.0…21.0 (low
gain)
8.0…33.0 (high
gain)
TrueWave
(Limited)
TrueWave-C
(Limited)
Metered NEND RX 1…36 (warm-up)
1.0…24.0 (low
gain)
11.0…36 (high
gain)
spanloss Port (E1) DSF (Full) Metered NEND RX 0.0…29.0
(warm-up)
0.0…17.0 (low
gain)
8.0…29.0 (high
gain)
DSF
(Limited)
Metered NEND RX 1.0…32.0
(warm-up)
1.0…20.0 (low
gain)
11.0…32.0…
(high gain)
spanloss Port (E1) NZ-DSF (Full) Metered NEND RX 0.0…33.0
(warm-up)
0.0…21.0 (low
gain)
8.0…33.0 (high
gain)
NZ-DSF
(Limited)
Metered NEND RX 1.0…36.0
(warm-up)
1.0…24.0 (low
gain)
11.0…36.0 (high
gain)
spanLossAvg Port (E1) SMF (Full)
ULL (Full)
Metered NEND RX n/a
SMF
(Limited)
ULL
(Limited)
Metered NEND RX n/a