L160 Raman Blade Operaonal Requirement and Consideraons
■ Minimum outside plant ber distance is 40 km
â–  Minimum span loss is 15 dB
■ Opcal return loss is greater than 17.6 dB
â–  Total Loss (bulk loss) between L160 Raman blade and the outside plan transmission line is lesser than 1 dB
â– 
Accumulated loss in the ber (splices and connectors loss), parcularly in the rst 20 km, should be kept to a
minimum as this could aect Raman gain. Performance is best with the cleanest possible transmission line.