102 Upgrade and Maintenance Manual CX2550/60/70 M4
Basic software procedures
Executing the fan test via the iRMC web interface
Ê Log into the iRMC web interface.
The System menu is displayed on default.
Ê Open the Cooling page.
Ê Expand the Cooling Devices group.
Ê Click Start Fan Test
I For more information on iRMC settings, see the iRMC user guides.
Executing the fan test via ServerView Operations Manager
Ê Open the ServerView Operations Manager and log in.
Ê Under Administration select Server Configuration.
Ê In the hierarchy tree of the Server list tab, select the server to be configured.
Ê In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO....
In the left-hand section of the window, the Configuration tab is being
activated.
Ê In the navigation area of the Configuration tab, select Other Settings.
Ê Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
Ê Click Save Page.
The fan test will be started at the specified time.
Ê After the fan test is complete, restore the time setting to its initial value and
click Save Page.
In case of maintenance done by Fujitsu engineers in Japan:
Executing the fan test via Chassis ID Prom Tool
I Please follow the instructions provided separately.